76 EVO Installation Guide
10.12 Power Failure Restore Report Delay
SECTION [3060]
(default = 030) The control panel will delay the transmission of the AC Failure Restore report code
programmed into section
[3972] by the period programmed into section [3060]. Enter any value between 001 and
255 to determine Power Failure Restore Report Delay in minutes.
10.13 Repeat Pager Report Code Transmission
SECTION [3059]
{default = 000) This feature re-sends the report code as specified.
10.14 Auto Test Report
SECTION [3037]: OPTIONS [3] AND [4] AND
SECTIONS [3040], [3041], [3042] AND [3043]
The control panel can transmit the test report code programmed into section [3902] every hour or after a period
of time.
10.15 Disarm Reporting Options
(default = disabled) When disabled, the control panel sends the Disarming Report Codes every time the
partition is disarmed. When enabled, the control panel sends the Disarming Report Codes to the monitoring
station only when the partition is disarmed following an alarm. Select the section that corresponds to the
desired partition and enable or disable option
[7]:
10.16 Zone Restore Report Options
SECTION [3037]: OPTION [8]
(default = disabled) When disabled, the control panel sends the Zone Alarm Restore report codes to the
monitoring station when the Bell Cut-Off Timer elapses
(see section 9.2) or when the alarm is disarmed. When
enabled, the control panel sends the Zone Alarm Restore report codes (see section 10.2) to the monitoring
station as soon as the zone returns to normal (zone closure) or upon disarming.
OFF OFF
Auto Test
Report Period
(default)
After the number programmed (000 to 255 days,
default = 000) in section [3040], the control panel
transmits a report code at the time (00:00 to 23:59,
default = 00:00) programmed in section [3041].
OFF ON
Timed Test
Transmission
when Armed/
Disarmed
When disarmed: The control panel transmits the code
at regular intervals. Program the number of minutes
(000 to 255, default = 060) between transmissions in
section [3043].
When armed: The control panel transmits the test
report code at regular intervals. Program the number
of minutes (000 to 255, default = 005) between each
transmission in section [3042].
ON OFF
Hourly Test
Transmission
The control panel will transmit the test report code
every hour on the minute value programmed in
section [3041] (the last two digits). Note that the first
two digits of section [3041] will be ignored.
ON ON
Timed and
Hourly Test
Transmission
The test report code will be transmitted when any of
the conditions of the second and third options listed
above (options [3] = OFF and [4] = ON / options [3] =
ON and [4] = OFF) are met.
Partition 1: [3123] Partition 3: [3323] Partition 5: [3523] Partition 7: [3723]
Partition 2: [3223] Partition 4: [3423] Partition 6: [3623] Partition 8: [3823]