56 EVO Installation Guide
8.7 Restrict Arming on Bell or Auxiliary Failure
SECTION [3035]: OPTION [3]
(default = disabled) When enabled, the control panel prevents arming if:
the bell or siren is disconnected
the Bell Output has exceeded its current limits
the Auxiliary Outputs have exceeded their current limits
8.8 Restrict Arming on TLM Failure
SECTION [3035]: OPTION [4]
(default = disabled) When enabled, the control panel can prevent arming if it is unable to access the telephone
line.
8.9 Restrict Arming on Module Troubles
SECTION [3035]: OPTION [5]
(default = disabled) When is enabled, the control panel uses the same Restrict Arming options for the modules
connected to the combus.
8.10 Timed Auto-Arming
(default = disabled) The control panel arms the selected partition every day at the time set (see section
8.10.1). A 60-second Exit Delay (default value) triggers before the partition arms. It can be cancelled or
postponed by entering a valid access code. If zones are open, the control panel arms the partition and
considers all open zones as temporarily bypassed (except 24hr. zones). The control panel transmits the Auto-
Arming report code programmed in section
[3910]. The control panel will transmit the Late to Close report
code programmed in section
[3912]. Enable option [1] in the desired section:
8.10.1 Auto-Arm Timer
Enter the time when the partition should arm in the desired section:
8.10.2 Postpone Auto-Arming
(default = 000) It is possible to postpone auto-arming for a preset amount of time by entering a valid user code
during the exit delay. The delay is set by entering a number between 001 and 255 in the appropriate section.
That number represents for how many increments of 15 minutes the arming will be postponed.
8.11 No Movement Auto-Arming
(default = disabled) If no movement occurs in a partition for the specified period, the control panel will
automatically arm that partition. The Auto-Arming Option determines the arming method
(see section 8.12).
The control panel will transmit the No Movement report code programmed in section [3913] upon arming. The
control panel will always transmit the Late to Close report code [3912]. Enable option [2] in the desired
section:
Partition 1: [3122] Partition 3: [3322] Partition 5: [3522] Partition 7: [3722]
Partition 2: [3222] Partition 4: [3422] Partition 6: [3622] Partition 8: [3822]
Partition 1: [3101] Partition 3: [3301] Partition 5: [3501] Partition 7: [3701]
Partition 2: [3201] Partition 4: [3401] Partition 6: [3601] Partition 8: [3801]
Partition 1: [3120] Partition 3: [3320] Partition 5: [3520] Partition 7: [3720]
Partition 2: [3220] Partition 4: [3420] Partition 6: [3620] Partition 8: [3820]
Partition 1: [3122] Partition 3: [3322] Partition 5: [3522] Partition 7: [3722]