70 EVO Installation Guide
10.2.10 Special Alarm Report Codes
10.2.11 System Trouble Codes
[3930]
Emergency Panic
(non-medical)
the panic keys [1] and [3] were pressed (see
section 9.6 on page 63)
[3931] Auxiliary Panic
the panic keys [4] and [6] were pressed (see
section 9.6 on page 63)
[3932] Fire Panic
the panic keys [7] and [9] were pressed (see
section 9.6 on page 63)
[3933] Recent Closing
an alarm is generated within the Recent
Close Delay (see section 10.10 on page 75)
[3934] Police Code
Confirmation of an alarm condition occurred
during the Police Code Timer’s delay (see
section 9.4 on page 62).
[3935]
Auto Zone
Shutdown
the control panel stops regenerating alarms
on a zone during the same armed period (see
section 4.6.1 on page 35)
[3936] Duress
a Duress enabled access code is keyed in (see
Keypad Installation Instructions on
page 106)
[3937] Keypad Lockout
too many invalid codes entered
(see section 8.19 on page 59)
[3941] AC Failure
AC power not detected. Also, see Power Fail
Report Delay in section 10.11
[3942] Battery Failure
battery is disconnected or the battery
voltage is less than or equal to 10.5V
[3943] Auxiliary Supply
the aux power supply’s current is greater
than or equal to 1.1A
[3944]
Bell Output
bell output is disconnected or the current is
greater than or equal to 3A
[3945]
Clock Loss panel time lost (see section 14.17)
[3946]
Fire Loop Trouble tamper on a Fire Zone (see section 4.4)
[3947] TO [3949]
Future Use
[3950] Bus Fault a module was removed from the combus
[3951] Module Tamper
tamper/wire fault on module (not a motion
detector) on the combus
[3952]
ROM Check Error on-board Read-Only Memory trouble
[3953] Module TLM
TLM failure detected on Listen-In Module
(DGP-LSN4)
[3954]
Module Fail to
Communicate
DGP2-DVAC failed to communicate with the
monitoring station
[3955]
Printer Fault Printer Module detected an error
[3956]
Module AC Failure no AC power detected on a module
[3957]
Module Battery
Failure
battery on a module is disconnected or the
battery voltage is low
[3958]
Module Auxiliary
Failure
the AUX output on a module has exceeded
current limits
[3959]
Future Use
[3960]
Wireless Trans-mitter
Low Battery
the battery voltage is low on a wireless
transmitter
[3961]
Wireless Module
Supervision Failure
this report code is global unless using the
Contact ID or SIA reporting formats
[3962] to [3964] Future Use
[3965]
Fail to Com 1 Phone Number 1 failed to communicate*
[3966]
Fail to Com 2 Phone Number 2 failed to communicate*
[3967]
Fail to Com 3 Phone Number 3 failed to communicate*
[3968]
Fail to Com 4 Phone Number 4 failed to communicate*