58 EVO Installation Guide
generated for every zone bypassed in that manner. Another event will be generated when the zone will be
closed. Enable option [8] in the desired section:
8.15 Auto Force on Stay Arming
(default = disabled) When enabled for a particular partition, the system will Force arm that partition whenever
Stay arming is activated. An event will be generated for every zone bypassed in that manner. Another event will
be generated when the zone will be closed. Enable option [4] in the desired section
8.16 Follow Zone Switches to Entry Delay 2
(default = enabled) When enabled and an Entry Delay zone is bypassed, an armed Follow Zone that opens
without an Entry Delay being triggered will switch to the partition’s Entry Delay 2. Enable option [8] in the
desired section:
8.17 One-Touch Features
(default = disabled) The One-Touch features can arm or disarm a partition, access Bypass Programming, or
display the Event Buffer by pressing and holding a specific key for 2 seconds instead of entering an access code.
If the keypad is assigned to more than one partition, the feature must be enabled in the corresponding
partitions. Select the section corresponding to the desired partition and enable or disable the desired options:
8.18 Exit Delay
(default = 060) The Exit Delay is the amount of time users have to leave the protected area before arming. It
applies to all zones, except 24Hr Zones. Program the Exit Delay from 001 to 255 seconds:
Partition 1: [3123] Partition 3: [3323] Partition 5: [3523] Partition 7: [3723]
Partition 2: [3223] Partition 4: [3423] Partition 6: [3623] Partition 8: [3823]
Partition 1: [3126] Partition 3: [3326] Partition 5: [3526] Partition 7: [3726]
Partition 2: [3226] Partition 4: [3426] Partition 6: [3626] Partition 8: [3826]
Partition 1: [3122] Partition 3: [3322] Partition 5: [3522] Partition 7: [3722]
Partition 2: [3222] Partition 4: [3422] Partition 6: [3622] Partition 8: [3822]
Partition 1: [3125] Partition 3: [3325] Partition 5: [3525] Partition 7: [3725]
Partition 2: [3225] Partition 4: [3425] Partition 6: [3625] Partition 8: [3825]
Optio
n
One-Touch Feature
One-Touch
Key
[1]
Regular Arming
[
ARM]
[2]
Stay Arming
[
STAY]
[3]
Instant Arming
[5]
[4]
Force Arming
[
FORCE]
[5]
Stay/Instant Disarming [DISARM]
[6]
Bypass Programming [BYP]
[7]
Event Record Display [7]
Partition 1: [3108] Partition 3: [3308] Partition 5: [3508] Partition 7: [3708]
Partition 2: [3208] Partition 4: [3408] Partition 6: [3608] Partition 8: [3808]