60 EVO Installation Guide
8.21 Ring-back
After disarming the system, the control panel can warn the user that there was an alarm and that it may be
dangerous to enter by having the keypad beep 10 times and/or by squawking the bell 10 times. The user
should leave immediately and contact the monitoring station from a secure location. Select the section that
corresponds to the desired partition and enable or disable the desired option (off = disabled) (default =
disabled):
8.22 Maximum Bypass Entries
(default = 000) The Maximum Bypass Entries feature limits the number of zones that can be bypassed in each
partition. Enter any value between 001 and 096 (000 = no limit).
8.23 Display “Bypass” If Armed
SECTION [3033]: OPTION [5]
(default = enabled) When enabled, the keypads will not display that zones have been bypassed while the
system is armed.
[3]
Auto-Arming
Emits 1 squawk every second for 60s before
Auto-Arming a partition. Emits a series of 3
squawks every second for 10s before arming
(default = disabled)
[4]
Exit Delay
Emits 1 squawk every second during the Exit
Delay. Emits a series of 3 squawks every second
during the final 10 seconds of the Exit Delay
(default = disabled)
[5]
Entry Delay
Emits 1 squawk every second during the Entry
Delay (default = disabled)
[6]
Remote Arming/
Disarming
Emits 1 squawk upon arming and 2 squawks
upon disarming with a remote control (using
the Magellan Wireless System, MG-RTX3
(default = enabled)
Partition 1: [3124] Partition 3: [3324] Partition 5: [3524] Partition 7: [3724]
Partition 2: [3224] Partition 4: [3424] Partition 6: [3624] Partition 8: [3824]
[7]
Bell Ring-back Bell or siren emits 10 squawks
[8]
Keypad Ring-back Keypad emits 10 beeps
Partition 1: [3115] Partition 3: [3315] Partition 5: [3515] Partition 7: [3715]
Partition 2: [3215] Partition 4: [3415] Partition 6: [3615] Partition 8: [3815]