EVO Installation Guide 131
Appendix H: EVO192 CP-01 Installer Programming Quick Reference Chart
SIA False Alarm Reduction
Minimum requirement system for SIA-FAR Installations :
• EVO192 CP-01 Control Panel
• Local Annunciation Devices
The local annunciation devices must be the following keypads.
• K641/K641+/TM50
Caution:
• For SIA FAR installations, only use modules / devices that are listed on this page.
• Fire Alarm Verification feature (Auto Verified Fire zone) is not supported on 2-wire
smoke detectors zones. This feature may be enabled for 4-wire smoke detectors only.
• Call Waiting Cancel feature on a non-Call Waiting line will prevent successful
communication to the central station.
• All smoke detectors on the system must be tested annually by conducting the Installer
Walk Test. Please refer to the smoke detector installation instructions on how to correctly
test the detectors.
CP-01
Paragrap
h
Installation Manual (IM)
/ User Manual (UM)
Feature Range
Shipping
default
Recommended
Programming*
4.2.2.1 (IM) 10.15 Exit time 45 sec – 255 sec 60 seconds 60 seconds
4.2.2.2 (UM) Keypad muting Progress annunciation
Individual keypads may be
disabled
All annunciators
enabled
All annunciators enabled
4.2.2.3 (IM) 10.XX Exit time restart For re-entry during exit delay
Always
Enabled
Cannot be disabled
4.2.2.5 (IM) 10.1
Auto Stay Arm on
Unvacated Premises
If no exit after full arm Enabled Enabled
4.2.3.1 (IM) 7.1.1 to 7.1.4 Entry delay(s) 30 sec – 255 sec** 30 seconds At least 30 sec**
4.2.5.1 (IM) 7.4.6
Abort Window – for non-
fire zones
May be disabled by zone Enabled Enabled (all zones)
4.2.5.1 (IM) 7.4.6
Abort Window Time – for
non-fire zones
15 sec – 45 sec** 30 seconds At least 30 sec**
4.2.5.1.2 (IM) 14.15 Abort annunciation
Annunciate that no alarm was
transmitted
Always
Enabled
Cannot be disabled
4.2.5.4 (IM) 14.16 Cancel window No limits No limits No limits
4.2.5.4.1 (IM) 14.16 Cancel annunciation
Annunciate that a cancel was
transmitted
Always
Enabled
Cannot be disabled
4.2.6.1 &
4.2.6.2
(IM) 5.5.8 Duress feature
No 1+derivative of another user
code. No duplicate with other
user codes.
Disabled Disabled
4.3.1 (IM) 7.4.5 Cross zoning Programming needed Disabled
Enabled and two (or more)
zones programmed
4.3.1 (IM) 7.4.5
Programmable cross
zoning
May Program 48 sec.
Per walk path n protected
premises
4.3.2 (IM) 7.4.1 Singer shutdown
For all non-fire zones, shutdown
at 1 or 2 trips
two trip two trip
4.3.3 (IM) 7.1.27 Fire Alarm Verification Depends on sensors Disabled
Enabled unless sensors can
self verify
4.5 (IM) XX Call waiting Cancel Depends on user phone line Disabled
Enabled if user has call
waiting
4.6.3 (IM) 14.8
System test (test report +
walk test mode + siren)
Test periodically. Disabled
Enabled to test all zones,
siren, communicator