132 EVO Installation Guide
Note:
• *Programming at installation may be subordinate to other UL requirements for the intended
application.
• **Combined Entry Delay and Abort Window should not exceed 1 minute.
• Cross zones have the ability to individually protect the intended area (e.g., motion detectors, which
overlap).
• Cross zoning is not recommended for line security Installations nor is it to be implemented on exit /
entry zones.
• There is a communicator delay of 30 seconds in this control panel. It can be removed, or it can be
increased up to 45 seconds at the option of the end user by consulting with the Installer.
• Do not duplicate any reporting codes. This applies for all communication formats other than SIA and
Contact ID sending automatic programmed reporting codes.
• The control unit must be installed with a local sounding device and an off-premise transmission for
SIA communication format.