EVO Installation Guide 87
System Settings and Commands 14
14.1 Hardware Reset
A Hardware Reset sets sections [0001] to [3991] to default. Only the Panel ID, PC Password, PC Telephone Number
and Event Buffer are not reset. The Installer Code Lock prevents Hardware Reset.
1. Make sure the Installer Code Lock is disabled
2. Press and hold the Reset and Aux buttons for 3 seconds
3. The panel will be reset to defaults
14.2 Software Reset
Performing a software reset will set certain parameters to default values or program certain sections with a set
of pre-defined values. To reset:
1. Enter Panel Programming Mode (see section 3.4).
2. Enter section [4049] to unlock software reset.
3. Enter the 4-digit
[SECTION] of the software reset you wish to perform.
4. For every other section your want to reset, you will have to unlock software reset.
[4040]
Resets the programmable sections from [0001] to
[3991] to default (even if Installer Code Lock is
enabled) except: Event Buffer, Panel ID, PC
Password, PC Telephone Number and Zone, Door,
Partition and User Labels (see section 15.4 on
page 97).
[4041]
Resets the System Master Code to 123456.
[4042]
Resets all Zone Programming sections from [0001]
to
[0196], [0201] to [0296] and [0961] to [0984] to default.
[4043]
Resets the Access Control sections, except Door
Labels, from [2201] to [2712] to default.
[4044]
Resets all User Access Code Programming sections
from [1001] to [1999] and
[2001] to [2199] to
default. User Labels (see section 15.4 on page 97)
will not be reset.
[4045]
Resets all control panel settings from [3020] to
[3043] and from [3900] to [3991] and all the
Dialer sections from [3051] to [3081].
[4046]
Resets all Partition Settings, except Partition
Labels, from [3101] to [3831] to default.
[4047]
Resets Keyswitch Programming sections from
[0501] to [0832] and all Programmable Outputs
sections from [0901] to [0939] to default.