EasyManuals Logo

Paradox EVO192 User Manual

Paradox EVO192
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #129 background imageLoading...
Page #129 background image
EVO Installation Guide 129
12. Zone definition options
a. ‘Delay alarm transmission’ enabled by default for all zones.
b. ‘Force zone’ disabled by default for all zones.
13. Auto Zone Shutdown Counter Section [712] = 1 (CP-01 default)
a. Section [3114] = 2 (CP-01 maximum 6)
b. Section [3214] = 2 (CP-01 maximum 6)
c. Section [3314] = 2 (CP-01 maximum 6)
d. Section [3414] = 2 (CP-01 maximum 6)
e. Section [3514] = 2 (CP-01 maximum 6)
f. Section [3614] = 2 (CP-01 maximum 6)
g. Section [3714] = 2 (CP-01 maximum 6)
h. Section [3814] = 2 (CP-01 maximum 6)
14. Partition options : enabled : Switch to stay arming if no zone entry delay is opened
a. Section [3121] option 1 enabled
b. Section [3221] option 2 enabled
c. Section [3321] option 3 enabled
d. Section [3421] option 4 enabled
e. Section [3521] option 5 enabled
f. Section [3621] option 6 enabled
g. Section [3721] option 7 enabled
h. Section [3821] option 8 enabled
15. Arming/Disarming options : Exit delay termination
a. Section [3122] option 4 disabled
b. Section [3222] option 4 disabled
c. Section [3322] option 4 disabled
d. Section [3422] option 4 disabled
e. Section [3522] option 4 disabled
f. Section [3622] option 4 disabled
g. Section [3722] option 4 disabled
h. Section [3822] option 4 disabled
ADD THESE NOTES TO THE INSTALLER MANUAL
16. At the beginning of the manual.
a. To comply with CP-01 standards, your system must be setup like this:
i All system keypads must be audible (Mute disabled).
ii A minimum of 2 must be installed to comply with CP-01 standards.
iii To be CP-01, remote panic action shall be programmed on combined button only ( ).
17. Recent closing delay.
a. If the option CP-01 is enabled (section [3028] opt 3), the recent closing delay will always be set to 120 sec and will not take care of the
programmed value.
18. Delay Alarm Transmission:
a. In accordance with UL standards, the Abort Window standard intends that the aggregate of the Entry Delay and Abort Window will not be
programmed to exceed one minute.
b. Non-effective on fire zones
19. Auto zone shutdown.
a. Auto zone shutdown counter is reset every 48 hours of no movement.
20. Intellizone
a. Sections [400] : Zones [001] to [192]
Option [7] OFF = Intellizone Disabled (default)
Option [7] ON = Intellizone Enabled for Selected Zone
This feature reduces the possibility of false alarms. When a zone with the Intellizone option opens, the panel does not immediately generate an
alarm. First it triggers the Intellizone Delay Timer. To program the Intellizone Delay Timer, key in the desired 3-digit value (000 to 255 seconds,
Default = 48 seconds) into section [3x10]( x = 1-8). If any of the following conditions occur during this period, the panel will generate an alarm:
• During the Intellizone Delay, a second zone has caused an alarm.
• During the Intellizone Delay, the zone in alarm has restored (closed) and re-occurred (opened). (Area options section [3x26](x=1-8) option 2 must
be disabled)
• The zone in alarm remains open for the entire Intellizone Delay. (Area options section [3x26](x=1-8) option 2 must be disabled)
21. Zone input specifications
a. Maximum loop current (shorted loop): 2.2 mA
b. Maximum loop voltage (open loop): 5.0 VDC

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox EVO192 and is the answer not in the manual?

Paradox EVO192 Specifications

General IconGeneral
BrandParadox
ModelEVO192
CategorySmoke Alarm
LanguageEnglish

Related product manuals