78 EVO Installation Guide
Dialer Options 11
11.1 Telephone Line Monitoring
SECTION [3036]: OPTIONS [1] AND [2]
When enabled, the system verifies the existence of the main telephone line once every second. After each
successful test, the Status LED on the control panel flashes briefly. A line test failure occurs when the TLM
detects less than 3 volts for the period defined by the TLM Fail Timer
(see section 11.1.1). If the line test fails,
the control panel will generate one or more conditions as defined by the TLM settings below, until it detects
the telephone line again. When the dialer detects a telephone ring, the TLM test stops for 1 minute.
11.1.1 TLM Fail Timer
SECTION [3053]
(default = 016) If the TLM does not detect the existence of the main telephone line for the time programmed in
this section, the control panel will generate the condition(s) defined by the TLM options
(see section 11.1).
Enter any value between 016 and 255 (value is X2 seconds) into section [3053]. Entering a value between 000
and 016 will set the TLM Fail Timer to 32 seconds.
11.2 Tone/Pulse Dialing
SECTION [3036]: OPTION [4]
(default = enabled)
11.3 Pulse Ratio
SECTION [3036]: OPTION [5]
(default = enabled) When using Pulse dialing (see section 11.2), select one of two Pulse Ratios. If the selected
pulse ratio does not provide adequate results, try the other one.
11.4 Busy Tone Detection
SECTION [3036]: OPTION [6]
(default = enabled) When enabled, the control panel immediately hangs up if it receives a busy signal when it dials an outside number.
[1] [2]
Feature When the line test fails
OFF OFF Disabled TLM disabled (default) .
ON OFF Trouble Only
The Communicator trouble appears in the
Trouble Display.
OFF ON
Alarm when
Armed
The Communicator trouble appears
in the Trouble Display. If the
partition is armed, the control panel
generates an alarm.
ON ON
Silent Alarms
become Audible
The Communicator trouble appears in the
Trouble Display. The control panel switches any
triggered Silent Alarm zones or Silent panic
alarms to an audible alarm.
[4]
ON Tone/DTMF format
[4]
OFF Pulse dialing format
[5]
ON North American pulse ratio of 1:1.5
[5]
OFF European pulse ratio of 1:2