90 EVO Installation Guide
14.11 Shabbat Feature
SECTION [3030]: OPTION [4]
(default = disabled) When enabled, addressable detectors and keypads in the system no longer display system
status through the LCD and/or LEDs between noon Friday and midnight Saturday. Normal operation is re-
instated Sunday at 12:00:01a.m. A user can access all the usual commands and features during the Shabbat
period by pressing a key or by entering their access code (depending on how Confidential Mode is configured
in the keypad). When no actions have occurred for two minutes, the Shabbat feature will re-activate. During the
Shabbat period:
the LCD keypads only display the date and time
the backlight is disabled
the LED indicators on modules are disabled
14.12 Installer Function Keys
Press and hold the [0] key and key in the [INSTALLER CODE] to access the installer functions and then:
For LCD keypads: Press the key indicated in the list below that corresponds to the function you wish to
activate.
For Grafica keypads: Press the center action key (Options), highlight the desired function and then press the
center action key (Ok).
[STAY]
TEST REPORT: Sends the Test Report report code
programmed in section
[3902] to the monitoring
station.
[FORCE]
CALL WINLOAD: Dials the PC telephone number
programmed in section
[3010] to communicate
using WinLoad.
[ARM]
ANSWER WINLOAD: Forces the control panel to
answer a call made by the monitoring station that
is using WinLoad.
[DISARM]
CANCEL COMMUNICATION: Cancels all
communication with the monitoring station or
WinLoad until the next reportable event.
[MEM]
INSTALLER TEST MODE: Perform walk tests where
the bell or siren squawks once when a zone opens
and twice when it closes. Press
[MEM] again to exit.
Partitions cannot be armed if the Installer Test
Mode is enabled.
[TRBL]
START MODULE SCAN: Verifies the status of
modules on the combus. The LCD Keypads display
the serial number of each module connected to
the combus.
[ACC]
START VOLTMETER READING (K641 only): Verifies if
the combus is supplying enough power at the
keypad’s location.