EVO Installation Guide 39
4.6.8 Delay Before Alarm Transmission
SECTION [0400]: OPTION [8]
S
ECTIONS [0101] TO [0196]: OPTION [8]
(default = 000) When an alarm condition occurs on a zone with option [8] enabled, the alarm will not be
reported to the monitoring station until the end of the Alarm Transmission Delay. Disarming the system cancels
any report originating from this zone. To program the Alarm Transmission Delay, access section
[3055].
4.7 Input Speed
(001 to 255 X 30msec, default = 600ms)
The Input Speed defines how quickly the control panel responds to an open zone detected on any hardwired
input terminal (does not apply to addressable motion detectors and door contacts). Set the Input Speed (001 to
255 X 30ms, default = 600ms):
4.8 EOL on Hardwire Zones
SECTION [3033]: OPTION [7]
(default = disabled) If detection devices connected to hardwired input terminals use 1kΩ end of line resistors,
enable option
[7] in section [3033]. For details on using EOL resistors, refer to "Addressable Zone
Connections"2.19 and Double Zone Connections on page 24.
4.9 Keypad Numbering
SECTIONS [2801] TO [2832]
Keypad Numbering identifies the keypad in the event buffer. The keypad is assigned to a Keypad Number from
1 to 32 through the keypad's serial number in sections [2801] to [2832].
[0961]
Input 01
[0973]
Input 13 (ATZ of Input 01)
[0962]
Input 02
[0974]
Input 14 (ATZ of Input 02)
[0963]
Input 03
[0975]
Input 15 (ATZ of Input 03)
[0964]
Input 04
[0976]
Input 16 (ATZ of Input 04)
[0965]
Input 05
[0977]
Input 13 (ATZ of Input 01)
[0966]
Input 06
[0978]
Input 14 (ATZ of Input 02)
[0967]
Input 07
[0979]
Input 15 (ATZ of Input 03)
[0968]
Input 08
[0980]
Input 16 (ATZ of Input 04)