EVO Installation Guide 71
10.2.12 System Trouble Restore Codes
If the Telephone Line Monitoring (see section 11.1) is disabled, the control panel will not transmit the
TLM report code.
10.3 Report Arming and Disarming
These features identify when partitions should be armed or disarmed. It allow the control panel to report
changes from the schedule.
10.3.1 Arming and Disarming Report Schedules
Arming and Disarming Report Schedules identify the days and times that a partition should be armed and
disarmed. Each schedule consists of 2 programmable time periods called Intervals that determine the time
span and days when the partition should be armed or disarmed
(see Figure 20). Schedules are enabled when
they are programmed.
Figure 20: Example of an Arming and a Disarming Report Schedule
* No “Fail to Communicate” for Pager
telephone numbers
[3970] TLM1 Restored [3981] Module Tamper Restored
[3971] AC Restored [3982] ROM Check Error Restored
[3972] Battery Restored [3983] Module TLM Restored
[3973]
Auxiliary Supply
Restored
[3984]
Module Fail to Communicate
Restored
[3974] Bell Output Restored [3985] Printer Fault Restored
[3975] Clock Loss Restored [3986] Module AC Failure Restored
[3976] Fire Loop Restored [3987] Module Battery Restored
[3977] Future Use [3988] Module Auxiliary Restored
[3978] Future Use [3989] Future Use
[3979] Future Use [3990]
Wireless Transmitter Battery
Restored
[3980] Bus Fault Restored [3991]
Wireless Module Supervision
Restored