EVO Installation Guide 113
C.0.29 Display Exit Delay Timer
SECTION [003]: OPTION [2]
Option [2] OFF=Will not display Exit Delay timer (default)
Option [2] ON=LCD screen will display Exit Delay timer
C.0.30 Display Entry Delay Timer
SECTION [003]: OPTION [3]
Option [3] OFF=Will not display the Entry Delay Timer (default)
Option [3] ON=LCD screen will display Entry Delay Timer
C.0.31 Confidential Mode
SECTION [003]: OPTIONS [4] AND [5]
Section [003]:
Option [4] OFF=Normal Mode (default)
Option [4] ON=Confidential Mode
Option [5] OFF=LCD screen activated by entering an access code (default)
Option [5] ON=LCD screen activated by pressing a button
C.0.32 Confidential Mode Timer
SECTION [007]
Section [007] determines the amount of time without action before the keypad enters Confidential Mode. The
Confidential Mode Timer can be set from 005 seconds to 255 seconds. Default: 120 secs.
C.0.33 Time Display Option
SECTION [003]: OPTION [8]
Option [8] OFF=Date displayed as yy/mm/dd (default)
Option [8] ON=Date displayed as dd/mm/yy
C.0.34 Muting
SECTION [004]: OPTION [1]
Option [1] OFF=Audible sounds (default)
Option [1] ON=Mute
C.0.35 Beep on Exit Delay
SECTION [004]: OPTION [2]
Option [2] OFF=Exit Delay beep disabled
Option [2] ON=Exit Delay beep enabled (default)
C.0.36 Chime on Zone Closure
SECTION [004]: OPTION [4]
Option [4] OFF=Chime on Zone Closure disabled (default)
Option [4] ON=Chime on Zone Closure enabled
C.0.37 Beep on Trouble
SECTION [005]: OPTIONS [1] TO [4]
O
ption [1] OFF=Beep disabled: System Troubles and Clock Loss
Option [1] ON=Beep enabled: System Troubles and Clock Loss
Option [2] OFF=Beep disabled: Communicator Troubles
Option [2] ON=Beep enabled: Communicator Troubles