EasyManuals Logo

Paradox EVO192 User Manual

Paradox EVO192
147 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #115 background imageLoading...
Page #115 background image
EVO Installation Guide 115
C.0.44 Door Unlocked Period Extension
SECTION [009]
The Door Unlocked Period Extension is the amount of time added to the Door Unlocked Period in section [008],
which leaves the door unlocked longer. This will allow those with this feature enabled on their User Access
Codes extra time to enter. Enter any value between 001 and 255 to determine the number of seconds to be
added to the time programmed in section [008]. Default = 15 secs.
C.0.45 Relock Door
SECTION [006]: OPTION [6]
Option [6] OFF=Locking device latches immediately (default)
Option [6] ON=Locking device latches when door closes
C.0.46 Door Unlocked Schedule
SECTION [017]
The Door Unlocked Schedule determines the hours, days, and holidays that the door will remain unlocked.
Program the Start Time and End Time according to the 24-hour clock within the same day. Use Feature Select
Programming to set the options representing the Days.
C.0.47 Card Activates Door Unlocked Schedule
SECTION [006]: OPTION [1]
Option [1] OFF=The Schedule activates without Card
Option [1] ON=Card activates Door Unlocked Schedule (default)
C.0.48 Door Left Open Access Alarm
SECTION [006]: OPTION [2]
Option [2] OFF=Door Left Open Alarm won’t be generated (default)
Option [2] ON=Door Left Open Alarm is enabled
C.0.49 Door Left Open Interval Before Access Alarm
SECTION [010]
Enter any value between 001 and 255 to determine the number of seconds the door may remain open before
the Access Alarm is triggered. Default = 60 secs.
C.0.50 Door Left Open Pre-Alarm
SECTION [004]: OPTION [3]
Program the Pre-Alarm timer in section [011].
Option [3] OFF=The Pre-Alarm will not be generated
Table 16: Door Unlocked Schedule
Option
Day
Option
Day
[1]
Sunday (S)
[5]
Thursday (T)
[2]
Monday (M)
[6]
Friday (F)
[3]
Tuesday (T)
[7]
Saturday (S)
[4]
Wednesday (W)
[8]
Holidays (H)
Table 17: Door Left Open Access Alarm
Section
[004]
Option [3] Door Left Open Pre-alarm
Option [5] Door Left Open Alarm
Option [6] Door Left Open Alarm follows
[010]
Door Left Open Interval
[011]
Door Left Open Pre-alarm Timer
[012]
Beep Timer for Door Left Open Alarm

Table of Contents