134 EVO Installation Guide
Recommended:
EOL resistor part #2011002000
Transformers: (Use a 17Vac (50/60Hz) transformer with a minimum 40VA rating. For residential installations use transformer made by Universal Power Group
model: UB1640W
AC/AC transformer:
For US: UL/ETL Listed Class 2 wall/building 120VAC/60Hz power supply with restraining means.
For Canada: CSA/ULc/ETLc Listed Class 2 Power Supply with NO restraining means
For CSA listed systems, use Basler Electronics’ transformer model #BE116240AAA.
12Vdc 7Ah rechargeable acid/lead backup battery (YUASA model #NP7-12 recommended) for residential use. 7Ah battery to comply with fire requirements.
All outputs are Class 2 or power-limited, except for the battery terminal.The Class 2 and power-limited fire alarm circuits shall be installed using CL3, CL3R, CL3P, or
substitute cable permitted by the National Electrical Code, ANSI/NFPA 70.
The control unit and keypads are intended to be programmed and installed as follows:
Household Fire Warning Systems (US and Canada)
At least one model K641 keypad shall be used with the system.
One listed audible device rated to operate over the range of 11.4 to 12.5Vdc and rated 85db minimum is required for this application. For example, Wheelock
model 46T-12 is compatible. The bell cutoff time shall be programmed for a minimum of 4 minutes (5 minutes for Canada).
The fire alarm initiating circuit shall employ the listed model 2011002000-PRT end-of-line resistor.
For Canadian systems, the secure screw for the listed Class 2 transformer shall not be employed.
Household Grade A Burglar Alarm system Unit (US and Canada)
At least one listed audible device rated to operate over the range of 11.4 to 12.5Vdc and rated 85db minimum. For example, Wheelock model 46T-12 is
compatible.
At least one model K641 keypad shall be used.
All initiating circuits shall be programmed and installed as end-of-line supervised.
Burglar alarm initiating devices shall be rated to operate over the range of 11.4 to 12.5Vdc.
The bell cutoff time shall be programmed for a minimum of 4 minutes.
The maximum entry delay shall not exceed 60 seconds. The maximum exit delay shall not exceed 45 seconds.
For Canadian systems, the secure screw for the listed Class 2 transformer shall not be employed.
Grade B Monitoring Station (Level 0)
Same as Household Grade A Burglar alarm system unit except:
The ringback feature shall be enabled (section [3037] option [5].
The model AB12M Bell and Bell Housing, manufactured by ADEMCO shall be employed. Bell cutoff time shall be programmed for a minimum of 15 minutes
(30 minutes for Canada).
The Auto Test Report setting must be programmed to send a test transmission to the monitoring station at least once every 24 hours (section [3037] options [3]
and [4] and section [3041].
Openings and closings must be reported to the monitoring station. Report codes shall be enabled.
Model 278-0000-035 attack resistant enclosure must be employed.
Grade C Monitoring Station (Level 0)
Same as Grade B Monitoring Station except the Grade A Bell housing may not be employed.
Grade A Local Alarm Units (Level 0)
Same as Grade B Monitoring Station except:
Bell test must be enabled.
Police Station Connect with Basic Line Security (Level 0)
Same as Grade B Monitoring Station except:
Openings and closings may not be reported to the monitoring station.
Access Control System
At least one model K641R keypad shall be used with the system.
The listed compatible model DGP-R915 reader shall be employed off the keypad.
Control of the Protected Premise
In order to have a UL certified system, the protected area is to be under the responsibility of one ownership and management (i.e. one business under one name).
This may be a group of buildings attached or unattached with different addresses but under the responsibility of someone having mutual interest. The person of
mutual interest is not the alarm installing company.
Bell Location
The alarm sounding device (bell) must be located where it can be heard by the person or persons responsible for maintaining the security system during the daily
arming cycle.
Protection of the Control Unit
The local control unit and the local power supply must be protected by one of the following ways:
The control unit and audible alarm device must be in a protected area, which is armed 24 hours a day.
Each partition shall arm the area protecting the control unit and the audible alarm device power supply. This may require duplicate protection armed by each
partition. Access to this protected area, without causing an alarm, will require that all partitions be disarmed
In all cases described above, the protected area for the control unit must be programmed as not bypassable.
CTR-21 Warnings
The equipment has been approved in accordance with Council Decision 98/482/EC for pan-European single terminal connection to the public switched telephone
network (PSTN). However, due to differences between the individual PSTNs provided in different countries, the approval does not, of itself, give an unconditional
assurance of successful operation on every PSTN network termination point. In the event of problems, you should contact your equipment supplier in the first
instance.
General Warning
This equipment must be installed and maintained by qualified service personnel only.