34 EVO Installation Guide
4.4.4 Instant Zones
SECTION [0400]: FIRST DIGIT = 4
S
ECTIONS [0101] TO [0196]: FIRST DIGIT = 4
When an armed Instant zone opens, the control panel immediately generates an alarm.
4.4.5 24Hr Buzzer Zones
SECTION [0400]: FIRST DIGIT = 5
S
ECTIONS [0101] TO [0196]: FIRST DIGIT = 5
Whenever a 24Hr Buzzer zone opens, the control panel activates the keypad buzzer to indicate that the zone
was breached. The control panel will report the alarm, but will not enable the bell/siren output. Enter any valid
access code on the keypad to stop the buzzer.
The keypads must be assigned to the same partition as the 24Hr Buzzer zone or the buzzer will not
activate. UL Note: Not to be used for perimeter protection.
4.4.6 24Hr Burglary Zones
SECTION [0400]: FIRST DIGIT = 6
S
ECTIONS [0101] TO [0196]: FIRST DIGIT = 6
When a 24Hr Burglary zone opens, the control panel will immediately generate a burglary alarm.
4.4.7 24Hr Hold-up Zones
SECTION [0400]: FIRST DIGIT = 7
S
ECTIONS [0101] TO [0196]: FIRST DIGIT = 7
When a 24Hr Hold-up zone opens, the control panel will immediately generate an alarm.
The SIA FSK reporting format includes specific codes to identify the alarm as a Hold-up, Gas, Heat, Water, or Freeze Alarm.
4.4.8 24Hr Gas Zones*
SECTION [0400]: FIRST DIGIT = 8
S
ECTIONS [0101] TO [0196]: FIRST DIGIT = 8
When a 24Hr Gas zone opens, the control panel will immediately generate an alarm.
4.4.9 24Hr Heat Zones**
SECTION [0400]: FIRST DIGIT = 9
S
ECTIONS [0101] TO [0196]: FIRST DIGIT = 9
When a 24Hr Heat zone opens, the control panel will immediately generate an alarm.
** UL Note: UL Listed compatible devices must be used for UL systems. For UL Listed systems, this type of zone should be programmed as a pulsing Fire alarm.
4.4.10 24Hr Water Zones*
SECTION [0400]: FIRST DIGIT = A
S
ECTIONS [0101] TO [0196]: FIRST DIGIT = A
When a 24Hr Water zone opens, the control panel will immediately generate an alarm.
4.4.11 24Hr Freeze Zones*
SECTION [0400]: FIRST DIGIT = B
S
ECTIONS [0101] TO [0196]: FIRST DIGIT = B
When a 24Hr Freeze zone opens, the control panel will immediately generate an alarm.
* UL Note: UL Listed compatible devices must be used for UL systems. For UL Listed systems, this type of zone must be programmed as a silent auxiliary alarm.
4.4.12 Delayed 24Hr Fire Zone (Not to be used with UL Listed systems)
SECTION [0400]: FIRST DIGIT = C
S
ECTIONS [0101] TO [0196]: FIRST DIGIT = C
The Delayed 24Hr Fire Zone definition from Figure 14 on page 38 is used in homes where a smoke detector
often generates false alarms. A zone programmed as Fire becomes normally open and requires an EOL resistor.