68 EVO Installation Guide
10.2.5 Access Codes Arming
SECTIONS [2001] TO [2099]
A report code can be programmed for each user access code from 01 to 98 in sections [2001] to [2098]. User
access codes from 99 to 999 use a common report code in section [2099]. The control panel can send the
report code identifying which access code was used to arm the system.
10.2.6 Access Codes Disarming
SECTIONS [2101] TO [2199]
A report code can be programmed for each user access code from 01 to 98 in sections [2101] to [2198]. User
access codes from 99 to 999 use a common report code programmed in section [2199].The control panel can
send the report code to the monitoring station identifying which access code was used to disarm the system. It
can be transmitted when a partition is disarmed or only following an alarm.
10.2.7 Special System Reporting Codes
When the system generates one of the following events, the control panel can send the report code to the
monitoring station identifying the event:
10.2.8 Special Arming Report Codes
When the partition arms using a special arming feature, the control panel can send the report code identifying
how the system was armed.
[3900]
Cold Start
control panel re-starts after complete
shutdown (total power loss)
[3901]
Warm Start
control panel resets due to sudden problem
other than power loss
[3902]
Test Report
report generated automatically
(see section 10.14)
[3903]
Listen-In to Follow
Listen-In module attempts to start a Listen-In
session
[3904]
WinLoad Login
Request
communication attempted between
WinLoad and control panel (Callback only)
[3905]
WinLoad Log Off
control panel ends communication with
WinLoad
[3906]
Installer In installer enters programming mode
[3907]
Installer Out installer exits programming mode
[3908] to [3909]
Future Use
[3910]
Auto-Arming when Auto-Arming (see section 8.10 on page 56)
[3911]
PC Arming system armed using WinLoad or NEware software
[3912]
Late to Close when Auto-Arming (see section 8.10 on page 56)
[3913]
No Movement
when No Movement Auto-Arming
(see section 8.11 on page 56)
[3914]
Partial Arming
when partitions are Stay, Instant or Force armed or
armed with bypassed zones
[3915]
Quick Arming
partitions armed with a One-Touch Arming feature
(see section 8.17 on page 58)
[3916]
Early to Close
partition armed before Arming Report Schedule
(see section 10.3.1 on page 71)
[3917]
Late to Close
partition armed after Arming Report Schedule (see
section 10.3.1 on page 71)
[3918]
Remote Arm
partition armed with the InTouch Voice-Assisted
Arm/Disarm Module (APR3-ADM2)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox EVO192 and is the answer not in the manual?

Paradox EVO192 Specifications

General IconGeneral
BrandParadox
ModelEVO192
CategorySmoke Alarm
LanguageEnglish

Related product manuals