D-140 Parameter Reference
AC30 series Variable Speed Drive
Parameters::Motor Control::Ramp
Rate of change of acceleration for the first segment of the curve in units of percent per second³, i.e. if the full speed of the machine is
1.25m/s then the jerk will be:
1.25 x 50.00% = 0.625m/s³
Parameters::Motor Control::Ramp
Rate of change of acceleration in units of percent per second³ for segment 2
Parameters::Motor Control::Ramp
Rate of change of acceleration in units of percent per second³ for segment 3
Parameters::Motor Control::Ramp
Rate of change of acceleration in units of percent per second³ for segment 4
Parameters::Motor Control::Ramp
When TRUE the output of the ramp is held at its last value
Parameters::Motor Control::Ramp
Parameters::Motor Control::Ramp
Input speed setpoint to the ramp