Parameter Reference D-141
AC30 series Variable Speed Drive
Parameters::Motor Control::Ramp
Parameters::Motor Control::Ramp
The setpoint is the target reference that the Drive will ramp to
Parameters::Motor Control::Ramp
The time that the Drive will take to ramp the jog setpoint from 0.00% to 100.00%.
Parameters::Motor Control::Ramp
The time that the Drive will take to ramp the jog setpoint from 100.00% to 0.00%.
Rate at which the demand is ramped to zero after the ramp has been quenched
Parameters::Motor Control::Ramp
Hold for zero speed detection used by stop sequences
Parameters::Motor Control::Ramp
Sets the time at which the Drive holds zero speed before quenching after a normal stop or a jog stop. This may be particularly useful if
a mechanical brake requires time to operate at zero speed, or for jogging a machine to position