D-206 Parameter Reference
AC30 series Variable Speed Drive
PNO
Name
Path
Type
Default
Range
Units
WQ
View
Notes
MBus
0435
VHz User Volts
Parameters::Motor Control::Fluxing VHz
ARRAY[0..10]
STOPPED
ENGINEER
01397
0436
VHz User Volts[0]
Parameters::Motor Control::Fluxing VHz
REAL
0.0
0.0 to 100.0
%
STOPPED
ENGINEER
01399
0437
VHz User Volts[1]
Parameters::Motor Control::Fluxing VHz
REAL
10.0
0.0 to 100.0
%
STOPPED
ENGINEER
01401
0438
VHz User Volts[2]
Parameters::Motor Control::Fluxing VHz
REAL
20.0
0.0 to 100.0
%
STOPPED
ENGINEER
01403
0439
VHz User Volts[3]
Parameters::Motor Control::Fluxing VHz
REAL
30.0
0.0 to 100.0
%
STOPPED
ENGINEER
01405
0440
VHz User Volts[4]
Parameters::Motor Control::Fluxing VHz
REAL
40.0
0.0 to 100.0
%
STOPPED
ENGINEER
01407
0441
VHz User Volts[5]
Parameters::Motor Control::Fluxing VHz
REAL
50.0
0.0 to 100.0
%
STOPPED
ENGINEER
01409
0442
VHz User Volts[6]
Parameters::Motor Control::Fluxing VHz
REAL
60.0
0.0 to 100.0
%
STOPPED
ENGINEER
01411
0443
VHz User Volts[7]
Parameters::Motor Control::Fluxing VHz
REAL
70.0
0.0 to 100.0
%
STOPPED
ENGINEER
01413
0444
VHz User Volts[8]
Parameters::Motor Control::Fluxing VHz
REAL
80.0
0.0 to 100.0
%
STOPPED
ENGINEER
01415
0445
VHz User Volts[9]
Parameters::Motor Control::Fluxing VHz
REAL
90.0
0.0 to 100.0
%
STOPPED
ENGINEER
01417
0446
VHz User Volts[10]
Parameters::Motor Control::Fluxing VHz
REAL
100.0
0.0 to 100.0
%
STOPPED
ENGINEER
01419
0447
Fixed Boost
Same as PNO 422
REAL
0.0
0.0 to 25.0
%
ALWAYS
TECHNICIAN
6
01421
0448
Auto Boost
Parameters::Motor Control::Fluxing VHz
REAL
0.0
0.0 to 25.0
%
ALWAYS
TECHNICIAN
6
01423
0450
Acceleration Boost
Parameters::Motor Control::Fluxing VHz
REAL
0.0
0.0 to 25.0
%
ALWAYS
TECHNICIAN
01427
0451
Energy Saving Enable
Parameters::Motor Control::Fluxing VHz
BOOL
FALSE
ALWAYS
TECHNICIAN
01429
0453
Vsd Demand
Parameters::Motor Control::Fluxing VHz
REAL
x.x
Min to Max
%
NEVER
TECHNICIAN
01433
0454
Vsq Demand
Parameters::Motor Control::Fluxing VHz
REAL
x.x
Min to Max
%
NEVER
TECHNICIAN
01435
0455
Rated Motor Current
Setup::Motor Control::Motor Nameplate
Parameters::Motor Control::Motor Nameplate
REAL
1.00
0.00 to 10000.00
A
STOPPED
TECHNICIAN
6
01437
0456
Base Voltage
Same as PNO 455
REAL
400.00
0.00 to 1000.00
V
STOPPED
TECHNICIAN
6
01439
0457
Base Frequency
Same as PNO 455
REAL
50.00
0.00 to 1000.00
Hz
STOPPED
TECHNICIAN
6
01441
0458
Motor Poles
Same as PNO 455
INT
4,
2 to 1000
STOPPED
TECHNICIAN
6
01443
0459
Nameplate Speed
Same as PNO 455
REAL
1420.00
0.00 to 100000.00
RPM
STOPPED
TECHNICIAN
6
01445
0460
Motor Power
Same as PNO 455
REAL
2.20
0.00 to 3000.00
kW
STOPPED
TECHNICIAN
6
01447
0461
Power Factor
Same as PNO 455
REAL
0.79
0.00 to 1.00
STOPPED
TECHNICIAN
6
01449
0464
100% Speed in RPM
Setup::Motor Control::Control and Type
Parameters::Motor Control::Scale Setpoint
REAL
1500.0
0.0 to 100000.0
RPM
ALWAYS
TECHNICIAN
01455
0467
PMAC SVC Auto Values
Parameters::Motor Control::PMAC SVC
BOOL
TRUE
ALWAYS
TECHNICIAN
6
01461
0468
PMAC SVC LPF Speed Hz
Parameters::Motor Control::PMAC SVC
REAL
60.00
0.00 to 10000.00
Hz
ALWAYS
TECHNICIAN
6
01463
0469
PMAC SVC P Gain
Parameters::Motor Control::PMAC SVC
REAL
1.00
0.00 to 10000.00
ALWAYS
TECHNICIAN
6
01465
0470
PMAC SVC I Gain Hz
Parameters::Motor Control::PMAC SVC
REAL
20.00
0.00 to 10000.00
Hz
ALWAYS
TECHNICIAN
6
01467
0476
PMAC SVC Open Loop Strt
Parameters::Motor Control::PMAC SVC
BOOL
TRUE
ALWAYS
TECHNICIAN
01479
0477
PMAC SVC Start Time
Parameters::Motor Control::PMAC SVC
TIME
0.500
0.000 to 1000.000
s
ALWAYS
TECHNICIAN
01481
0478
PMAC SVC Start Cur
Setup::Motor Control::SVC PMAC
Parameters::Motor Control::PMAC SVC
REAL
10.0
0.0 to 200.0
%
ALWAYS
TECHNICIAN
01483
0479
PMAC SVC Start Speed
Same as PNO 478
REAL
5
0 to 200
%
ALWAYS
TECHNICIAN
01485
0484
Seq Stop Method VHz
Setup::Motor Control::Control and Type
Parameters::Motor Control::Ramp
USINT
(enum)
1
0:DISABLED VOLTAGE
1:RAMP
2:STOP RAMP
3:DC INJECTION
ALWAYS
TECHNICIAN
01495
0485
Ramp Type
Parameters::Motor Control::Ramp
USINT
(enum)
0
0:LINEAR
1:S RAMP
ALWAYS
TECHNICIAN
01497
0486
Acceleration Time
Same as PNO 484
TIME
10.000
0.000 to 3000.000
s
ALWAYS
TECHNICIAN
01499
0487
Deceleration Time
Same as PNO 484
TIME
10.000
0.000 to 3000.000
s
ALWAYS
TECHNICIAN
01501
0488
Symmetric Mode
Parameters::Motor Control::Ramp
BOOL
FALSE
ALWAYS
TECHNICIAN
01503
0489
Symmetric Time
Parameters::Motor Control::Ramp
TIME
10.000
0.000 to 3000.000
s
ALWAYS
TECHNICIAN
01505
0490
Sramp Continuous
Parameters::Motor Control::Ramp
BOOL
FALSE
ALWAYS
TECHNICIAN
01507
0491
Sramp Acceleration
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s²
ALWAYS
OPERATOR
01509
0492
Sramp Deceleration
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s²
ALWAYS
TECHNICIAN
01511
0493
Sramp Jerk 1
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s³
ALWAYS
TECHNICIAN
01513
0494
Sramp Jerk 2
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s³
ALWAYS
TECHNICIAN
01515
0495
Sramp Jerk 3
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s³
ALWAYS
TECHNICIAN
01517
0496
Sramp Jerk 4
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%/s³
ALWAYS
TECHNICIAN
01519
0497
Ramp Hold
Parameters::Motor Control::Ramp
BOOL
FALSE
ALWAYS
TECHNICIAN
01521
0498
Ramping Active
Parameters::Motor Control::Ramp
BOOL
NEVER
TECHNICIAN
01523
0499
Ramp Spd Setpoint Input
Parameters::Motor Control::Ramp
REAL
x.x
-200.0 to 200.0
%
NEVER
TECHNICIAN
01525
0500
Ramp Speed Output
Parameters::Motor Control::Ramp
REAL
x.x
-200.0 to 200.0
%
NEVER
TECHNICIAN
01527
0501
Jog Setpoint
Parameters::Motor Control::Ramp
REAL
10.0
0.0 to 100.0
%
ALWAYS
TECHNICIAN
01529
0502
Jog Acceleration Time
Parameters::Motor Control::Ramp
TIME
1.000
0.000 to 3000.000
s
ALWAYS
TECHNICIAN
01531
0503
Jog Deceleration Time
Parameters::Motor Control::Ramp
TIME
1.000
0.000 to 3000.000
s
ALWAYS
TECHNICIAN
01533
0504
Stop Ramp Time
Same as PNO 484
TIME
10.000
0.000 to 600.000
s
ALWAYS
TECHNICIAN
01535
0505
Zero Speed Threshold
Parameters::Motor Control::Ramp
REAL
0.1
0.0 to 100.0
%
ALWAYS
TECHNICIAN
01537
0506
Zero Speed Stop Delay
Parameters::Motor Control::Ramp
TIME
0.500
0.000 to 30.000
s
ALWAYS
TECHNICIAN
01539
0507
Quickstop Time Limit
Parameters::Motor Control::Ramp
TIME
30.000
0.000 to 3000.000
s
ALWAYS
TECHNICIAN
01541