Technical Specifications F-8
AC30 series Variable Speed Drive
Power Supply = 380-480V ±10%, 50/60Hz 5%
Motor power, output current and input current must not be exceeded under steady state operating conditions.
Minimum repetitive power up / power down cycle time = 10 mins
Product Code
Motor Power
Output Current
(A)
Input Current
(A)
Estimated
Efficiency
Switching Frequency
(kHz)
nominal / maximum
Output Current Derate %/kHz
(applied above nominal switching
frequency)
FRAME J : Input currents for kW ratings are at 400V 50Hz ac input and for Hp ratings at 460V 60Hz ac input. Prospective short circuit current 10kA.
Normal Duty (Output Overload Motoring 110% for 60s)
31x-4J0180…
90kW
180
160
98%
2.5 / 8
8.1%
125Hp
156
147
31x-4J0205…
110kW
205
198
98%
2.5 / 8
8.4%
150Hp
180
175
31x-4J0260…
132kW
260
236
98%
2.5 / 8
8.7%
200Hp
240
231
Heavy Duty (Output Overload Motoring 150% for 60s, 180% for 3s short term rating)
31x-4J0180…
75kW
145
137
98%
2.5 / 8
7.5%
100Hp
124
119
31x-4J0205…
90kW
180
164
98%
2.5 / 8
8.6%
125Hp
156
148
31x-4J0260…
110kW
205
199
98%
2.5 / 8
8.0%
150Hp
180
177

Table of Contents