EasyManua.ls Logo

Philips Strand Lighting - Emptying the Programmers Content

Philips Strand Lighting
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Guide 500ML Lighting Control Console
82 Programming
With Values
Figure 146 illustrates how the programmer appears when fixtures are selected with values assigned in the
programmer. The programmer takes precedence over cuelist output for the attributes with values in the programmer.
However, these values would not be recorded.
Figure 146: Programmer With Values
Modified (Touched) Values
Figure 147 shows how the programmer appears when attribute values are modified (touched) in the programmer. The
programmer takes precedence over cuelist output for all attributes with values in the programmer. As soon as values
are "touched" (indicated by red background color of the corresponding cell) they can be recorded.
Figure 147: Programmer with Modified (Touched) Values
Emptying the Programmers "Content"
In order for all playbacks to re-gain control over the fixture attributes contained in the programmer, the programmer
needs to be cleared out. This happens in three steps with each press of the [CLEAR] key.
The first press of the [CLEAR] key will un-touch all values, however they are still in the programmer overriding the
playback. The second press of the [CLEAR] button will remove all values from the programmer and playback values
will be output again. The third and last press will unselect all fixtures that were selected.
Note: In case you accidentally cleared your programmer content, press [SHIFT] and [CLEAR] simultaneously to
revert to the previous values.
The LEDs above the [CLEAR] and the [I], [F], [C] and [B] buttons indicate the current state of the values:
Figure 148: Clear and IFCB Buttons
LED Color State
Green Fixtures are selected (Only applies to [CLEAR] key)
Yellow There are values in the programmer and the corresponding attribute group
Red
There are modified (touched) values in the programmer and the
corresponding attribute group that may be recorded

Table of Contents