Parameters:
time: Forward-delay interval (4-30 sec)
Example:
To set the forward-delay parameter:
WGSW-28040(config)# spanning-tree forward-delay 20
Maximum Age
Description:
Changes the interval between messages the spanning tree receives from the root switch
Syntax:
spanning-tree maximum-age <time>
Parameters:
time: Interval the switch waits between receiving BPDUs from the root switch (6-40 sec)
Example:
To set the maximum age parameter:
WGSW-28040(config)# spanning-tree maximum-age 20
Tx Hold Count
Description:
Set spanning-tree tx hold count, in seconds
Syntax:
spanning-tree tx-hold-count <time>
Parameters:
time: Specifies the tx hold count (1-10 sec)
Example:
To set the tx hold count:
WGSW-28040(config)# spanning-tree tx-hold-count 10
Path Cost
Description:
Sets the path cost for specified port
Syntax:
spanning-tree port <port_list> path-cost <cost>