Application > PGL Setup > Lead PDF Dist
Adjusts the leading and trailing character spacing distance of the PDF for
UPC/EAN barcodes. The value can be modified in 0.01 inch increments.
Minimum
0.01 inches
Maximum
0.10 inches
Factory Default
0.10 inches
Application > PGL Setup > Trunc Dyn Data
This menu allows the user to truncate the dynamic data up to the maximum
data length specified in Create Mode.
Disable
If the dynamic data exceeds the maximum data length,
an error will report.
Enable
If the dynamic data exceeds the maximum data length,
the data truncates.
Factory Default
Disable
Application > PGL Setup > Boundary Check
This option turns on or off the page boundary check for all print elements.
Disable
No out of bound error is reported. The out of bound
print element prints over the page boundary.
Enable
An out of bound error is reported if the print element is
out of the page boundary.
Factory Default
Enable
Application > PGL Setup > Preparser
Allows you to send preparser commands to the printer through any port.
Disable
Not using the Preparser command.
Enable
The preparser command can be accepted from any
port.
Factory Default
Disable