Application > PGL Setup > I-2/5 Selection
This option is added to be compatible with a special IGP-X00 customization.
Usually, if Interleaved 2/5 bar codes have an odd number of digits, a leading
zero is inserted in front of the data. However, this special IGP-X00
customization gives you the option of adding a space character at the end of
the bar code instead.
Leading Zero
A leading zero is inserted in front of the data.
Trailing Space
A space is inserted at the end of the data instead of a
leading zero.
X2 DPD
When selected, I-2/5 bar code with a magnification X2
will use the specially configured ratios 3:3:6:5 rather
than 3:6:9:12 for compatibility issues.
Modulo 7 CD
The I-2/5 bar code uses a modulo 7 check digit instead
of the default modulo 10 check digit.
Factory Default
Leading Zero
Application > PGL Setup > C39 Compatbl.
This menu makes the old method of decoding C39 alternative character set
compatible with the new.
Disable
Uses the proper way of decoding.
Enable
Matches the old legacy IGP-100 method of decoding.
Factory Default
Disable
Application > PGL Setup > User-Def Ratio
This option allows you to ignore the user-defined barcode ratio and replace it
with the default ratio (X1).
Disable
The user-defined barcode ratio will be replaced with
the default ratio (X1).
Enable
This option allows you to ignore the user-defined
barcode ratio and replace it with the default ratio (X1).
Factory Default
Enable