EasyManua.ls Logo

Printronix T6000 - Page 181

Printronix T6000
320 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
181
Host IO > Serial > Idle Response
This option is for the Series1 protocol and is relevant when the buffer is less
than 75% full.
Disable
The printer does not send a response character when
the buffer is less than 75% full..
Enable
The printer sends a response character every two
seconds while the buffer is less than 75% full.
Factory Default
Disable
Host IO > Serial > One Char Enquiry
The One Char Enquiry mode uses the Poll Character to detect a request
from the host and sends a response back to the host. This option also allows
you to turn on and off this feature.
Printer State
Response (hex)
ONLINE and Buffer Not Full
22
ONLINE and Buffer Full
23
OFFLINE and Buffer Not Full
20
OFFLINE and Buffer Full
21
The Poll Character is removed from the data stream. If the Data Protocol is
set to ETX/ACK, ACK/NAK, or Series1, One Char Enquiry is automatically
disabled.
Disable
Enable
Factory Default
Disable

Table of Contents

Other manuals for Printronix T6000