Table 13. LCD Message Troubleshooting
1284 OPTION CARD
PROGRAM FAILED
----------------------------------
PRESS KEY TO CONTINUE
Status message indicating that the IEEE1284 option card
FPGA failed to program.
1. Pressing any key on the panel will cause the printer to
continue boot-up with the previous FPGA configuration.
No action is required.
1284 OPTION CARD
PROGRAM COMPLETE
--------------------------------
RESUMING BOOT_UP
Status message indicating that the IEEE1284 option card
FPGA was successfully programmed.
No action is required.
+48 VDC: an internal
power failure.
1.
Power off the printer for 15
seconds, then power back on.
2.
If the problem persists, contact
your authorized customer
service representative.
The application tried to use
an undefined VFU
channel.
1.
Change the application to use defined channels.
BAR CODE IMPROPER
Data Format
Data validation error: the bar code is not properly encoded. For
example, a check sum is incorrect, a required number of
characters are not found, or the required terminator characters
are not included. This problem is almost always caused by
incorrect form or host application design.
1.