Table 13. LCD Message Troubleshooting
BAR CODE QUIET
Zone too small
Data validation error: the blank zone(s) left or right of the bar code
is not big enough to meet the minimum requirement.
Typically, this occurs in forms where bar codes are placed too
close to other elements, the bar code is too close to an edge of the
media, or the media’s position is shifting.
The minimum quiet zone on each end of the bar code should be
ten times the minimum element width or 1/4 inch, whichever is
greater. In addition, between bar codes, the validator requires a
minimum distance of 20 times the minimum element width or
1/2 inch, whichever is greater.
1.
Fix application.
2.
Disable Quiet Zone in the VALIDATOR menu.
Host sent data after the
printer buffer was full
(serial interface).
1.
Verify that the printer
matches the host serial
interface
configuration
settings for Data Protocol,
Baud Rate, Data Bits,
Stop
Bits, Parity, Data Terminal
Ready, and Request to
Send.
2.
Set printer serial interface
parameters to match those
of the
host.
Receive overrun (serial
interface).
1.
Verify that the printer
matches the host serial
interface
configuration
settings for Data Protocol,
Baud Rate, Data Bits,
Stop
Bits, Parity, Data Terminal
Ready, and Request to
Send.
2.
Set printer serial interface
parameters to match those
of the
host.
Calibration values
derived from Manual
Calibrate were not
acceptable.
1.
Run Manual Calibrate again.
CANNOT
CALIBRATE
Disable Peel-Off
Calibrate was
attempted with Peel-Off Media Handling
selected.
NOTE: You can
perform Auto Calibrate
in Peel-Off mode if
Cal
in Peel Mode = Enable.
Be prepared to catch
labels during
Auto
Calibrate.
1.
Select another option in the Media > Handling > Media
Handling menu.
2.
Enable Sensors > Calibrate > Cal in Peel Mode.