285
Table 27. General PTX_SETUP Commands
Command
Sub-Command
Parameter
Description
CONFIG
PNE_PORT
Port
This command selects the port that
the PNE will use to communicate to
the printer.
The valid ports are:
DISABLE
ETHERNET
USB
NOTE: If ETHERNET is selected
but not enabled, the selection will
revert to DISABLE.
PANEL
LOCK
UNLOCK
This command locks the operator
out of the printer’s configuration
menu.
This command unlocks the printer’s
configuration menu and allows the
operator access to the menus. By
default, the menu is unlocked.
PNE_PORT_NUM
Port Number
This command sets the Port
Number the PNE uses to
communicate to the printer if the
PNE Port was set to Ethernet. This
command causes the printer to
automatically reboot.
PXML_PORT_NUM
Port Number
This command sets the Port
Number the PXML and UCP will use
to communicate to the printer if the
PXML Port is set to Ethernet. This
command causes the printer to
automatically reboot.
LP MODE
n/a
Protocol
Protocol must be 0-4. This
command resets the software
protocol, and is selected as follows:
0 - P-Series
1 - P-Series XQ
2 - Serial Matrix
3 - Proprinter III XL
4 - Epson FX-1050

Table of Contents