Chapter 8: Getting Information About the Library
Viewing the Location of the Robot
Quantum Scalar i40 and Scalar i80 User’s Guide 209
The triangle represents the robot. If it is filled in, then the robot
contains the media, otherwise the robot is empty. The direction
the triangle points to indicates its location.
The right information section provides the following:
Describes the current or last operation performed. If the
operati
on performed affects a device location, the description
will be numericfor example Move Media: [1,2,5] to [1,5,1]. If
the operation affects a slot location, such as unlocking a
magazine, the description will be textual —for example, Unlock:
Left Magazine.
Provides the status of the operation—Active, Completed, or
Fa
iled.
2 F
or additional information about the status, select Details.
This screen provides details for the library status:
Last Operation - Status of last completed operation—
Succee
ded or Failed.
Robot - The Robot location refers to where the robot was at the
en
d of the operation. For example, if the robot is between two
slots, it will display the robot location as “Robot: At [0,1,4] -
[0,1,5]”. If it is directly in front of a slot, it would then read, for
example “At [0,4,4]”.
Picker - Extended or Retracted.

Table of Contents

Other manuals for Quantum Scalar i80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i80 and is the answer not in the manual?

Quantum Scalar i80 Specifications

General IconGeneral
Power supply typeAC
Power requirements100 – 240V, 50/60Hz
Power consumption (typical)200 W
Dimensions (WxDxH)445 x 793 x 264 mm
Media types supported2x LTO-4
Maximum supported storage capacity128 TB
Storage temperature (T-T)-40 - 60 °C
Operating temperature (T-T)10 - 35 °C
Operating relative humidity (H-H)20 - 80 %
Media typeTape Cartridge
Form factor6U
Product typeStorage auto loader & library
CertificationIEC 60950, Class A / FCC part 15, ICES-003, CISPR 22, EN55022 Class A, VCCI, CNS 13438, KN22, AS/NZS CISPR 22, EN61000-3-2, EN61000-3-3 EN55024, KN24 CE, VCCI, GS, FCC, ICES, NRTL, GOST, BSMI, KCC
Product colorBlack
Standard interfacesFiber Channel
Weight and Dimensions IconWeight and Dimensions
Weight23800 g