EasyManua.ls Logo

Ricoh B039 - Page 131

Ricoh B039
513 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trouble-
shooting
SERVICE CALL CONDITIONS
SM 4-5 B039/B040/B043
No.
Definition
Symptom Possible Cause
Lower paper tray lift motor malfunction (optional two-tray paper tray unit)504 B
The paper lift sensor fails to activate
twice continuously after the tray lift
motor has been on for 18 seconds.
• Paper lift sensor defective
• Tray lift motor defective
• Too much load on the drive
mechanism
• Poor tray lift motor connection
Paper tray motor lock (optional paper tray units)506 B
A motor lock signal is not detected for
more than 1.5 s or the lock signal is not
detected for more than 1.0 s during
rotation.
• Paper tray unit motor defective
• Too much load on the drive
mechanism
Fusing thermostat/thermistor open541 A
The fusing temperature detected by the
thermistor is below 10°C for 5 seconds
after the main power switch is turned
on.
• Fusing thermostat defective or out of
position
• Fusing thermistor defective or out of
position
• Power supply board defective
Fusing temperature warm-up error542 A
The fusing temperature does not reach
80°C within 30 seconds after the main
switch is turned on.
• Fusing thermistor defective or out of
position
• Fusing lamp open
• Fusing thermostat open
• Fusing thermofuse open
• Power supply board defective
Fusing overheat error543 A
A fusing temperature of over 230°C is
detected for 1 second by the fusing
thermistor.
• Fusing thermistor defective
• Power supply board defective
Fusing low temperature error544 A
A fusing temperature of lower than
100°C is detected for 1 second by the
fusing thermistor during operation or
stand-by mode.
• Fusing lamp open
• Fusing thermistor defective
• Power supply board defective
• Fusing thermistor open
• Fusing thermostat open
Unstable fusing temperature546 A
The fusing temperature does not rise
3 °C or more within 5 seconds after the
fusing lamp has been on over 8
seconds.
• Thermistor defective
• Power supply unit defective
Zero cross signal malfunction547 B
Zero cross signals are not detected
within 5 seconds after the main power
switch is turned on, or are not detected
within 1 second after operation begins.
• Power supply board defective
• IOB defective
• BiCU defective
Communication error between IOB and ADF620 B
The IOB does not receive a response
from the ADF main board for 4 seconds
or more.
• Poor connection between the IOB and
ADF main board (DF connector)
• ADF main board defective
• IOB defective

Table of Contents