Fax Unit B404
NCU PARAMETERS
SM 5-45 B404
5.4 NCU PARAMETERS
The following tables give the RAM addresses and the parameter calculation units
that the machine uses for ringing signal detection and automatic dialing. The
factory settings for each country are also given. Most of these must be changed by
RAM read/write (Function 06-0), but some can be changed using NCU Parameter
programming (Function 08-0); if Function 08-0 can be used, this will be indicated in
the Remarks column. The RAM is programmed in hex code unless (BCD) is
included in the Unit column.
Address Function Unit Remarks
680400 Country code for NCU parameters Use the Hex value to program the
country code directly into this address,
or use the decimal value to program it
using Function 08-0 (parameter C.C.).
Country Decimal Hex
France 00 00
Germany 01 01
UK 02 02
Italy 03 03
Austria 04 04
Belgium 05 05
Denmark 06 06
Finland 07 07
Ireland 08 08
Norway 09 09
Sweden 10 0A
Switzerland 11 0B
Portugal 12 0C
Holland 13 0D
Spain 14 0E
Israel 15 0F
USA 17 11
Asia 18 12
Hong Kong 20 14
South Africa 21 15
Australia 22 16
New Zealand 23 17
Singapore 24 18
Malaysia 25 19
China 26 1A
Taiwan 27 1B
Korea 28 1C
Greece 33 21
Hungary 34 22
Czech 35 23
Poland 36 24
680401 Line current detection time
680402 Line current wait time
680403 Line current drop detect time
20 ms
Line current detection is
disabled.
Line current is not
detected if 680401
contains FF.