EasyManua.ls Logo

Ricoh B039 - Page 256

Ricoh B039
513 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Detailed
Descriptions
IMAGE FUSING AND PAPER EXIT
SM 6-63 B039/B040/B043
Copying (North America Model)
Sampling cycle: 1 second
Soft start setting: 3 cycles
Current minus Target
Previous minus Current
–3°
°°
°C or
less
–2°
°°
°C or
–1°
°°
°C
0°
°°
°C
+1°
°°
°C or
+2°
°°
°C
+3°
°°
°C or
more
-3°C or less
100% 100% 100% 100% 0%
From –2°C to –1°C
100% 70% 70% 70% 0%
0°C
100% 50% 30% 30% 0%
From +1°C to +2°C
100% 30% 0% 0% 0%
+3°C or more
100% 0% 0% 0% 0%
Ratio (%): The proportion of time that the fusing lamp power is on
Copying (Europe Model)
Sampling cycle: 1 second
Soft start setting: 10 cycles
Current minus Target
Previous minus Current
–3°
°°
°C or
less
–2°
°°
°C or
–1°
°°
°C
0°
°°
°C
+1°
°°
°C or
+2°
°°
°C
+3°
°°
°C or
more
3°C or less
100% 100% 100% 0% 0%
From –2°C to –1°C
100% 100% 100% 0% 0%
0°C
100% 100% 100% 0% 0%
From +1°C to +2°C
100% 100% 100% 100% 0%
+3°C or more
100% 100% 100% 100% 0%
Ratio (%): The proportion of time that the fusing lamp power is on
Standby
Sampling cycle: 1 second
Soft start setting: 3 cycles (Europe model: 20 cycles)
Current minus Target
Previous minus Current
–3°
°°
°C or
less
–2°
°°
°C or
–1°
°°
°C
0°
°°
°C
+1°
°°
°C or
+2°
°°
°C
+3°
°°
°C or
more
3°C or less
100% 100% 0% 0% 0%
From –2°C to –1°C
100% 100% 0% 0% 0%
0°C
100% 100% 0% 0% 0%
From +1°C to +2°C
100% 100% 100% 0% 0%
+3°C or more
100% 100% 100% 0% 0%
Ratio (%): The proportion of time that the fusing lamp power is on

Table of Contents