7.Detailed Descriptions
249
7. Detailed Descriptions
Guidance for Those Who are Familiar with Predecessor
Products
Quick Start-up method (Fusing
sleeve belt method)
Transport motor controls paper transport
line and fusing unit.
Fusing motor has been added,
so paper transport line and
fusing unit are controlled
separately.
AC current
detection
circuit
AC detection board installed to
control fusing suited for input
voltage.
A PSU cooling fan has been
provided to cope with the heat
caused by the additional 24V
load due to modifications in the
fusing method.
Fusing
thermopile,
NC sensor,
anti-
condensatio
n fan
• Thermopile and NC
sensor provided to
monitor the temperature of
the fusing sleeve belt.
• Thermistors provided to
monitor the temperature of
the pressure roller.
• Anti-condensation fan
provided to prevent