Remote Commands in the Receiver Application
R&S
®
ESW
498User Manual 1177.6298.02 ─ 08
OUTPut<ou>:IF:SCALe[:VALue] <Scale>
This command defines the scale of the transferred signal.
Available for the following output types:
●
AM
●
FM
Suffix:
<ou>
.
Output
Parameters:
<Scale> Numeric value whose unit depends on the output type:
• % for AM output
• Hz for FM output
Example: //Select a scale of 100 kHz for FM output on output 1
OUTP:IF FM
OUTP:IF:SCAL 100KHZ
Manual operation: See "Scale" on page 166
OUTPut<ou>:IF[:SOURce] <Type>
This command selects the type of signal data that is output.
Suffix:
<ou>
.
Output
Parameters:
<Type> AM
Outputs the AM signal.
FM
Outputs the FM signal.
FOCus
Outputs the data of the currently selected measurement window.
Available for analog demodulation.
IF
Outputs the IF signal.
Unavailable for audio output.
OFF
Turns off the output.
VIDeo
Outputs the video signal.
Unavailable for audio output.
Example:
//Select output of AM signal data
OUTP:IF:SOUR AM
Manual operation: See "Selecting the output type" on page 164