Remote Commands in the Receiver Application
R&S
®
ESW
502User Manual 1177.6298.02 ─ 08
This command works only if you have selected a user defined output with
OUTPut<up>:TRIGger<tp>:OTYPe.
Suffix:
<up>
.
1..n
<tp> Selects the trigger port to which the output is sent.
2 = trigger port 2 (front)
3 = trigger port 3 (rear)
Parameters:
<Level> HIGH
5 V
LOW
0 V
*RST: LOW
Example:
OUTP:TRIG2:LEV HIGH
Manual operation: See "Level" on page 168
OUTPut<up>:TRIGger<tp>:OTYPe <OutputType>
This command selects the type of signal generated at the trigger output.
Suffix:
<up>
.
1..n
<tp> Selects the trigger port to which the output is sent.
2 = trigger port 2 (front)
3 = trigger port 3 (rear)
Parameters:
<OutputType> DEVice
Sends a trigger signal when the R&S ESW has triggered inter-
nally.
TARMed
Sends a trigger signal when the trigger is armed and ready for
an external trigger event.
UDEFined
Sends a user defined trigger signal. For more information see
OUTPut<up>:TRIGger<tp>:LEVel.
*RST: DEVice
Manual operation: See "Output Type" on page 168