Remote Commands in the Receiver Application
R&S
®
ESW
633User Manual 1177.6298.02 ─ 08
[SENSe:]CORRection:SWITch:LOAD <FileName>
This command restores a previously saved dataset that controls a switch matrix.
Parameters:
<FileName> String containing the file name and path.
Example:
CORR:SWIT:LOAD 'X:\Dataset.xml'
Restore a dataset on drive X:\.
Usage: Event
[SENSe:]CORRection:SWITch:NAME <Name>
This command defines a name for a dataset that controls a switch matrix.
Parameters:
<Name> String containing the name of the dataset.
The dataset name is not necessarily the file name (if you save
the dataset).
Example:
CORR:SWIT:NAME 'SWITCH'
Defines a dataset name.
Manual operation: See "Dataset name and file name" on page 325
[SENSe:]CORRection:SWITch:OPC <State>
This command turns synchronization (with *OPC) for commands transmitted in each
transducer range on and off.
Parameters:
<State> ON | OFF
*RST: ON
Example:
CORR:SWIT:OPC ON
Synchronizes the commands in each transducer range.
Manual operation: See "Command sequence synchronization" on page 326
[SENSe:]CORRection:SWITch:RANGe<range>[:COMMand] <Commands>
This command defines commands to be sent to the switch matrix in a certain trans-
ducer range.
Suffix:
<range>
.
1...10
Selects the transducer range.