Improving Level Performance
R&S
®
SMA100B
217User Manual 1178.3834.02 ─ 05
The "Overview" tab shows the list of detected sensors, and provides a separate tab
per sensor.
A sensor tab contains all parameters for configuring the sensor settings, like aver-
age or peak display, reference source, filter and level offset.
The remote commands required to define these settings are described in Chap-
ter 13.15, "SENSe, READ, INITiate and SLISt Subsystems", on page 498, includ-
ing the triggering of the measurement and the retrieval of measurement results.
See also Chapter 7.5, "How to Calibrate the Power Level with an R&S NRP Power
Sensor", on page 264.
Settings
Sensor type and serial number................................................................................... 218
Level (Peak) / Level (Average) ...................................................................................218
Sensor Mapping..........................................................................................................218
Sensor settings........................................................................................................... 218
└ State .............................................................................................................218
└ Zero ..............................................................................................................218
└ Display.......................................................................................................... 218
└ Permanent ......................................................................................... 218
└ Display ...............................................................................................219
└ Use Frequency Of.........................................................................................219
└ Frequency ....................................................................................................219
└ Level Offset State,Level Offset..................................................................... 219
└ Filter..............................................................................................................219
└ Filter Length..................................................................................................220
└ Noise/Signal Ratio........................................................................................ 220
└ Auto Once.....................................................................................................220
└ Timeout......................................................................................................... 220
└ Default Aperture Time...................................................................................221
Using Power Sensors