148User Manual 1178.3834.02 ─ 05
The set dot length determines the length of the dash, the symbol space and letter
space of the Morse code.
"User"
You can set each length value separately.
Remote command:
[:SOURce<hw>][:ILS]:MBEacon:COMid:TSCHema on page 572
Dot Length
Sets the length of a Morse code dot.
If "Time Schema > Standard", the dot length value determines also the length of the
dash (= 3 times the dot length), symbol space (= dot length) and letter space (= 3 times
the dot length).
Remote command:
[:SOURce<hw>][:ILS]:MBEacon:COMid:DOT on page 570
Dash Length
Requires "Time Schema > User".
Sets the length of a Morse code dash.
Remote command:
[:SOURce<hw>][:ILS]:MBEacon:COMid:DASH on page 569
Symbol Space
Requires "Time Schema > User".
Sets the length of the Morse code symbol space.
Remote command:
[:SOURce<hw>][:ILS]:MBEacon:COMid:SYMBol on page 571
Letter Space
Requires "Time Schema > User".
Sets the length of a Morse code letter space.
Remote command:
[:SOURce<hw>][:ILS]:MBEacon:COMid:LETTer on page 571
5.5 ADF Configuration and Settings
Option: R&S SMAB-K25
Access:
Select "Modulation > Avionic Standards > ADF".
The remote commands required to define ADF settings are described in Chap-
ter 13.16.2.3, "SOURce:ADF Subsystem", on page 548.