Remote Control Commands
R&S
®
SMA100B
570User Manual 1178.3834.02 ─ 05
Parameters:
<Dash> float
Range: 0.05 to 1
Increment: 1E-4
*RST: 0.3
Example: See Example "Configure and generate an ILS marker beacons
signal" on page 544.
Manual operation: See "Dash Length" on page 148
[:SOURce<hw>][:ILS]:MBEacon:COMid:DEPTh
<Depth>
Sets the AM modulation depth of the COM/ID signal.
Parameters:
<Depth> float
Range: 0 to 100
Increment: 0.1
*RST: 5
Example: See Example "Configure and generate an ILS marker beacons
signal" on page 544.
Manual operation: See "Depth" on page 147
[:SOURce<hw>][:ILS]:MBEacon:COMid:DOT <Dot>
Sets the length of a Morse code dot.
Parameters:
<Dot> float
Range: 0.05 to 1
Increment: 1E-4
*RST: 0.1
Example: See Example "Configure and generate an ILS marker beacons
signal" on page 544.
Manual operation: See "Dot Length" on page 148
[:SOURce<hw>][:ILS]:MBEacon:COMid:FREQuency <Frequency>
Sets the frequency of the COM/ID signal.
Parameters:
<Frequency> float
Range: 0.1 to 20E3
Increment: 0.01
*RST: 1020