Remote Control Commands
R&S
®
SMA100B
453User Manual 1178.3834.02 ─ 05
:CALCulate[:POWer]:SWEep:TIME:MATH<ch>:STATe <State>
Activates the trace mathematics mode for "Time" measurement. This feature enables
you to calculate the difference between the measurement values of two traces. For fur-
ther calculation, a math result can also be assigned to a trace.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
CALC:POW:SWE:TIME:MATH1:STATe
Switches on math mode.
Options: R&S SMAB-K28
Manual operation: See " Mathematics - Trace Power Analysis " on page 228
:CALCulate[:POWer]:SWEep:TIME:MATH<ch>:SUBTract
<Subtract>
Subtracts the operands 1 and 2 and assigns the result to the selected trace in "Time"
measurement mode.
Parameters:
<Subtract> T1T1 | T1T2 | T1T3 | T1T4 | T1REf | T2T1 | T2T2 | T2T3 | T2T4 |
T2REf | T3T1 | T3T2 | T3T3 | T3T4 | T3REf | T4T1 | T4T2 |
T4T3 | T4T4 | T4REf
Example:
CALC:POW:SWE:TIME:MATH4:SUBT T2REF
Subtracts the Reference and Trace 2, and assigns the result to
Trace 4. The resulting curve is shown in the diagram.
Options: R&S SMAB-K28
Manual operation: See " Mathematics - Trace Power Analysis " on page 228
13.14.2 DISPlay Subsystem
:DISPlay[:WINDow][:POWer]:SWEep:BACKground:COLor.................................................453
:DISPlay[:WINDow][:POWer]:SWEep:GRID:STATe............................................................454
:DISPlay[:WINDow][:POWer]:SWEep:BACKground:COLor <Color>
Defines the background color of the measurement diagram. The selected color applies
also to the hardcopy of the diagram.
Parameters:
<Color> BLACk | WHITe
*RST: BLACk
Example:
DISP:SWE:BACK:COL WHIT
The measurement is indicated with a white background.
Manual operation: See " Background Color - Power Analysis " on page 236
Power Sensor Measurement Subsystems