Remote Control Commands
R&S
®
SMA100B
650User Manual 1178.3834.02 ─ 05
[:SOURce<hw>]:SWEep:POWer:EXECute
[:SOURce<hw>]:SWEep[:FREQuency]:EXECute
Executes an RF frequency sweep.
The command performs a single sweep and is therefore only effective in manual
sweep mode.
Example: See Example "Setup an RF frequency or power sweep"
on page 643.
Usage: Event
Manual operation: See " Execute Single Sweep " on page 175
[:SOURce<hw>]:SWEep:POWer:RETRace
<State>
[:SOURce<hw>]:SWEep[:FREQuency]:RETRace <State>
Activates that the signal changes to the start frequency value while it is waiting for the
next trigger event.
You can enable this feature, when you are working with sawtooth shapes in sweep
mode "Single" or "External Single".
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Setup an RF frequency or power sweep"
on page 643.
Manual operation: See "Retrace" on page 173
[:SOURce<hw>]:SWEep:POWer:RUNNing?
[:SOURce<hw>]:SWEep[:FREQuency]:RUNNing?
Queries the current sweep state.
Return values:
<State> 0 | 1 | OFF | ON
Example: See Example "Setup an RF frequency or power sweep"
on page 643.
Usage: Query only
[:SOURce<hw>]:SWEep[:FREQuency]:STEP:LOGarithmic <Logarithmic>
Sets a logarithmically determined step width for the RF frequency sweep. The value is
added at each sweep step to the current frequency.
See Chapter 6.2.1, "Correlating Parameters in Sweep Mode", on page 164.