10. Press [▶].
11. Set the correcon values for the feed direcon "F" and the scan direcon "S."
(1) Press [▲] or [▼] to set the correcon value for the feed direcon (F).
F:+0.30 +0.35mm
S:-0.40 -0.45mm
(2) Press [◀] or [▶] to set the correcon value for the scan direcon (S).
F:+0.30 +0.35mm
S:-0.40 -0.45mm
(3) When you have nished seng the correcon values, press [ENTER].
12. Press [MENU], then [▲] to display the screen shown below.
13. Press [ENTER].
The test paern (C&C1) is printed and cut. If the prinng and cung lines are aligned, adjustment is com-
plete. If further adjustment is needed, press [▼], then [▶] to go back to step 11 and ne-tune the adjust-
ment.
MEMO
• Default sengs
• F (correcon value of the media feed direcon): 0.00 mm
• S (correcon value of the cung carriage movement direcon): 0.00 mm
• Depending on the changes in the condion of media caused by laminang and the loading posion of the media before
cung, the posioning of cung may be misaligned. In such cases, refer to the following page.
RELATED LINKS
・ P. 179 "Correcng the Misalignment of Prinng and Cung with Crop Marks (Separate Test for Prinng/Cung with Crop
Marks)"
Accurately Adjusting the Settings for Cutting with Crop Marks