9 Technical data
9.1 Data sheet CLV 480-0010 bar code scanner
Type CLV 480-0010
Design line scanner (standard device), without heater
Reading window front
Laser diode (wave length) red light (λ = 650 nm)
MTBF of laser diode 20,000 h
Laser class of device
Class 2 (pursuant to EN 60825-1), shutoff of laser diode after 10 min
1)
Focus Control event-controlled focus control
No. of distance configurations (DC) max. 8
Focus adjustment time 20 ms (typically)
Focus trigger source "IN 0" to "IN 4" switching inputs/data interface/timer/OTS height information
Useful aperture angle max. 60° (front reading window)
Scanning/decoding frequency 600 to 1,200 Hz
Resolution (typically) 0.25 to 1.0 mm (9.8 to 39.4 mil)
Reading ranges see Page 10-3
Bar code print contrast (PCS) 60 %
Ambient light compatibility 2,000 lux (on bar code)
No. of bar codes per scan 1 to 12 (standard decoder), 1 to 5 (SMART decoder)
No. of bar codes per reading interval
2)
1 to 50 (autodiscriminating)
Bar code types Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved
Bar code length max. 50 characters (max. 600 characters across all bar codes per reading interval)
Print ratio 2:1 to 3:1
No. of multiple reads 1 to 99
Optical indicators 4 x LEDs (status indicators)
Reading pulse "Sensor" switching input (additionally "IN 4") /Free-running/data interface/OTS trigger
"Host" data interface RS 232 or RS 422/485, variable data output format
Data transmission rate 300 to 57,600 bd
Protocols SICK Standard, SICK Network and 3964(R)
Physical configurations Stand-alone, SICK Network (Bus), Daisy Chain (Pass-Through or Master/Slave)
"CAN" data interface CANopen protocol, CAN Scanner Network
Data transmission rate 10 kbit/s to 1 Mbit/s
"Terminal" data interface RS 232, 9,600 bd, 8 data bits, no parity, 1 stop bit, fixed output format
Switching inputs 6 ( Sensor, "IN 0" to "IN 4")
optodecoupled, V
imax
= +30 V, non-interchangeable, can be connected to PNP outputs
"Sensor" (reading pulse): max. internal delay 30 ms, reduced max. 2 to 6 ms
"IN 0" to "IN 4": focus position switching, IN 3 and IN 4: selectable function,
max. internal delay 30 ms
Switching outputs 4 ("Result 1" to "Result 4")
PNP, short-circuit-proof,
variable pulse duration (static; resolution 10 to 990 ms or 100 to 9 900 ms)
Variable output function for result status
Operating voltage/power consumption 18 to 30 V DC pursuant to ICE 364-4-41/ typically 11 W, max. 16 W
Electrical connections 1 x 15-pin D Sub HD plug, 1 x 15-pin D Sub HD socket
Housing Aluminium die-cast, does not represent a problem in paint shops
1) Default setting, in Reading mode with the "Switching input sensor" and "Serial interface pulse" types.
2) Reading interval: time window generated internally for evaluating the code.
Table 9-1: Technical specifications of the CLV 480-0010