Operating Instructions Chapter 10
CLV 480 Bar Code Scanner
8 010 080/O824/10-02-2005 © SICK AG · Division Auto Ident · Germany · All rights reserved 10-35
Appendix
10.6.5 Functions
The "CLV-Setup" program features (version V 4.0) the following functions to carry out:
Uploading the default parameter set from the database of CLV-Setup
Automatic communication attempt with the CLV when the program is started
Automatic software compatibility check in the CLV
Uploading and displaying parameter set stored in the CLV
Changing the parameter/parameter values on the tabs
CLV Assistant for simplified parameterization (not for CLV 480)
Downloading the changes to the parameter set in the CLV
Saving the changes to the parameter set as a configuration file "*.scl"
Printing the configuration files
Exporting the configuration files in RTF format
Exporting the command strings contained in the profile bar codes in ASCII format
Printing the parameter set in the form of profile bar codes (not for CLV 480)
Organizing logically serveral scanners in projects
Online access to the CLV via a Terminal Emulator (select operating mode, start
operating functions, log file for communication between the CLV and CLV-Setup,
extended Terminal mode, e. g. for displaying CLV messages)
AutoBaud Detect for automatic communication setup with the CLV
Selecting the COM port of the PC for adapting the data transfer parameters
Monitoring the data communication of the CLV host interface
Selecting language setting
Selecting units of measure
Displaying the last 10 configuration files that were processed
Saving the CLV type that was selected last
Automatic storage confirmation prompt when changes are made to the configuration file
Wizards for individual functions
CLV 490 only: I/O monitoring
Setting switches for starting the program (in the "CLVmain.ini" file)
Hot keys [F keys] for important functions (using the program without a mouse)
Starting program with SCL file as argument
Macro player for recording and playing a macro file
Context-sensitive help via the [F1] key
10.6.6 Hot keys
[F1] Start "CLV-Setup Help“ online
[F2] Open dialog box to execute device functions
[F3] Upload complete set of parameters from CLV
[F4] Download complete set of parameters to CLV
[F5] Open configuration file
[F6] Save configuration file
[F7] Load default setting of CLV from CLV-Setup database
[F8] Start AutoBaud Detect
[F9] Load operating data from CLV to be displayed and reset

Table of Contents