Operating Instructions Chapter 6
CLV 480 Bar Code Scanner
8 010 080/O824/10-02-2005 © SICK AG · Division Auto Ident · Germany · All rights reserved 6-25
Operation
6.5 Operating modes and outputing the reading result
The following CLV operating modes/functions (and more) can be selected in CLV-Setup:
Standard operating mode:
Reading mode
For setup:
Percentage evaluation
Adjusting mode
For adapting the device to the application at hand:
Configuring (parameterizing ) the CLV.
See Chapter 6.4.1 Configuring the CLV via the user interface of CLV-Setup, Page 6-5
Show CP-limits
For monitoring purposes/trouble shooting:
I/O monitor in incremental pulse
Display and edit operating data
Reading diagnosis
Monitor host interface
Auxiliary input
Self-test
6.5.1 Reading mode (standard operating mode)
The CLV performs a self-test after it has been switched on. It switches to Reading mode
("Device Ready" LED lights up). In the default setting the "Sensor" switching input is the (ex
-
ternal) trigger source of the reading pulse. The reading result is output by the CLV at the end
of the reading pulse via the host interface (default setting) and terminal interface.
Depending of the configuration, the "Result 1" to "Result 4" switching outputs become live
for the predefined pulse length when defined events occur during the reading process (e. g.
Good Read).
The reading result of the terminal interface can be displayed in the CLV-Setup Terminal
Emulator. The CLV terminal interface must be set to the R
EADING DIAGNOSIS mode for this pur-
pose. This mode is selected for the default setting. The reading result of the terminal inter-
face has a fixed, invariable format.
The Reading mode can be called up by choosing VIEW in the menu bar or via the Terminal
Emulator.
Line scanner with oscillating mirror:
In the Reading mode the CLV deflects (by default) the scan line about the position CW = 50
at a frequency of 1
Hz and a maximum angle of ±20°. 50 CW corresponds to an angle of
deflection of 105
°.