Display Device or configura‐
t
ion
Meaning
Display flashes
All devices and config‐
ur
ations
Contamination error. All safety outputs in the
OFF state. Check the optics cover for damage.
Clean the optics cover.
Display flashes
All devices and config‐
ur
ations
Dazzle warning. Check whether the safety laser
scanner is being dazzled by an external light
source in the scan plane, e.g., sun, halogen
light, infrared light source. Remove or cover the
light source.
Display flashes
All devices and config‐
ur
ations
Dazzle error. The associated safety outputs are
in the OFF state. Check whether the safety
laser scanner is being dazzled by an external
light source in the scan plane, e.g., sun, hal‐
ogen light, infrared light source. Remove or
cover the light source.
Display flashes
Configuration with ref‐
er
ence contour field
Tamper protection. The safety laser scanner
does not detect any contour within the config‐
ured tolerance band of the reference contour
field. All safety outputs in the OFF state.
Display flashes
All devices and config‐
ur
ations
Tamper protection. The safety laser scanner
measures no values within the distance meas‐
urement range in an area of at least 90°. All
safety outputs in the OFF state.
All devices and config‐
urations
Safety function stopped. All safety outputs in
the OFF state. Restart the device using the
keypad or Safety Designer.
All devices and config‐
ur
ations
The safety laser scanner has not yet received
a valid monitoring case number. All safety out‐
puts in the OFF state.
After switching on, the safety laser scanner
waits for a valid input signal. During this time,
an invalid input signal does not result in a
fault.
The message is also displayed during the pas‐
sivation of the device in the PROFINET (e.g.
after communication error or connection termi‐
nation).
All devices The device is not configured. The device is in
t
he as-delivered state or has been reset to
factory settings. All safety outputs in the OFF
state.
All devices and config‐
ur
ations
Sleep mode. All safety outputs in the OFF
state. Press any pushbutton to obtain more
information.
OPERATION 9
8021219/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
141
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
BrandSICK
ModelmicroScan3
CategoryScanner
LanguageEnglish

Related product manuals