Page #65 background image
Figure 43: How the restart interlock works (3): person in hazardous area, no detection in protec‐
t
ive field, safety output still in OFF state
Figure 44: How the restart interlock works (4): the reset pushbutton must be pressed before
restarting the machine.
DANGER
H
azard due to unexpected starting of the machine
b
Affix the control switch for resetting the restart interlock outside the hazardous
area.
b
Make sure that the control switch cannot be activated by a person who is in the
hazardous area.
b
Also make sure that the person activating the control switch has a complete view
of the hazardous area.
PROJECT PLANNING 4
8021219/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 – PROFINET
65
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 and is the answer not in the manual?

SICK microScan3 Specifications

General IconGeneral
Scanning angle275°
Power supply24 V DC
Supply voltage24 V DC ± 20%
Enclosure ratingIP65
Resolution70 mm
Protective field range5.5 m
Number of fields128
InterfaceEthernet
Safety integrity levelSIL3
Performance levelPL e
Ambient temperature+50°C
Scanning range5.5 m