Minimum Typical Maximum
Storage temperature range –25 °C +50 °C
+70 °C
(≤
24 h)
Humidity (taking into account the operating temper‐
a
ture range)
IEC 614961, section 5.1.2 and 5.4.2
IEC 61496-3, section 5.4.2
Height above sea level during operation 2,300 m
Protective field range
Short Range 4.00 m
Medium Range 5.50 m
Long Range 7.00 m
Range of services
Advanced 4 protective fields and warning fields
(
field sets)
Professional 8 protective fields and warning fields
(field sets)
Vibration IEC 61496-1, section 5.1.2 and 5.4.4.1
IEC 614963, section 5.4.4.2
Frequency range 10 Hz 150 Hz
Amplitude 0.35 mm or 5 g
Shock resistance IEC 614961
IE
C 61496-3
Single shock 15 g, 11 ms (EN 60068-2-27)
Continuous shock 10 g, 16 ms
Sender Pulsed laser diode
Wavelength 880 nm 905 nm 935 nm
Divergence of collimated beam 2.5 mrad
Pulse duration 3.1 ns
Average output power 562 µW
Light spot size at front screen 12 mm
Light spot size at 4.0 m scanning range 23 mm
Light spot size at 5.5 m scanning range 27 mm
Light spot size at 7.0 m scanning range 32 mm
Housing
Material Die-cast aluminum
Color RAL 1021 (colza yellow)
Front screen
Material Polycarbonate
Interface Outside with scratch-resistant coating
System plug ESD-protected
Dimensions
3)
Height 224 mm
Width 155 mm
Depth 160 mm
Overall weight 3.3 kg
1)
For detailed information on the safety configuration of the machine/system, please consult your SICK
sub
sidiary.
12 T
ECHNICAL DATA
112
O P E R A T I N G I N S T R U C T I O N S | S3000 PROFINET IO, S3000 PROFINET IO-OF 8013291/ZA19/2019-11-14 | SICK
Subject to change without notice